Leybold
| Klinger is the U. S. authorized distributor for this world renown supplier of quality science demonstration equipment. Request their free 500 page catalog (also available on CD) from Klinger. Follow this link directly to Leybold's web site. http://www.ld-didactic.de/data_e/index.html If any item is not listed on our site, Please call our toll free for information and/or pricing. (800) 522 6252 |
39 Item(s) Page 1 of 2 | 1 2 Next >>
30011 Saddle Base
Cylindrical base with clamping screw for fastening rods and plates. The rectangular groove at the bottom allows the device to be shifted along a linear scale (e.g. 311 02) or a ruler. The groove in the middle serves as a fixture for clamping a linear scale (e.g. 311 03). Technical Data...
Click to view
311902 Rotating platform
For experiments in which certain components are to be continuously turned and the respective angles determined either with a recorder or via a computer interface (CASSY), e.g. diffraction experiments with ultrasonics, angular distribution of micro-waves. The system is driven by a DC gear motor...
Click to view
33211 IR Position Detector
Opto-electronic measuring instrument for registering the oscillations of gravitation torsion balances. Measuring principle: four IR-diodes successively emit infrared light, which is reflected onto a row of phototransistors by the concave mirror mounted on the gravitation torsion balance. A...
Click to view
33747USB VideoCom USB
Single-line CCD camera for high-resolution registration of motions and relative measurement of intensities. For connection to the USB port of a computer. Including software for recording and evaluating measurements. Technical Data •2048 pixels When registering positions, the positions...
Click to view
46032 Precision Optical Bench with Standardized V-Shaped Cross-Section, 1 m (46032)
For use in demonstration experiments and in the laboratory, meeting the highest requirements. Including base, levelling screw for 3-point support. The front ends have bore holes for inserting connecting elements for further rails.
Click to view
460373 Optics rider 60/50 (460373)
For precision optical bench with standardized V-shaped cross-section (460 32, 460 33).
For demonstrations and lab experiments with high precision. Black anodized aluminium profile machined with highest mechanical accuracy. For optical elements mounted on rods of 10 � 13.7 mm dia.
...
Click to view
460374 Rider 90/50 (460374)
For precision optical bench with standardized V-shaped cross-section.
For demonstrations and lab experiments with high precision. Black anodized aluminium profile machined with highest mechanical accuracy. For optical elements mounted on rods of 10 � 13.7 mm dia.
Technical Data...
Click to view
471830 He-Ne Laser, Linearly Polarized
Ideal light source for all experimental setups in which an intensive and parallel light bundle is required (e.g. diffraction, interference or holography). As a result of the linear polarization, this laser is also suitable for experiments on the rotation of the plane of polarization and on light...
Click to view
50105 High voltage cable, 1 m
Experiment cable with measuring plug for voltages which are non-hazardous. Technical Data •Length: 1 m
Click to view
521545 DC Power Supply 0...16 V, 0...5A
Universal power supply, as constant voltage operation with current limiting and as constant current operation with voltage limiting, parallel working and series operation of several devices are possible. Technical Data •Output voltage : 0...16 V, continuously adjustable •Output...
Click to view
524010USB Sensor - CASSY
Cascadable interface for measured-value recording. •for connection to the USB port of a computer, another CASSY module or the CASSY display •Sensor-CASSY and Sensor-CASSY USB can be used mixed •fourfold electrically isolated (inputs A and B, relay R, voltage source S). •cascading...
Click to view
55477 LiF Crystal for Bragg Reflection (55477)
Designed to fit the goniometer of the x-ray apparatus(554 801). For experiments in Braggs configuration, e.g. diffraction(up to the 5th order), x-ray spectra, wavelength determination, Duane and Hunts displacement law, determining Planks constant, dependence of absorbtion on wavelength,...
Click to view
55478 NaCl Crystal for Bragg Reflection (55478)
Designed to fit the goniometer of the x-ray apparatus(554 801). For experiments in Braggs configuration, e.g. diffraction(up to the 5th order), x-ray spectra, wavelength determination, Duane and Hunts displacement law, determining Planks constant, dependence of absorbtion on wavelength,...
Click to view
554801 X-ray Apparatus Mo, Complete
Fully-featured, microprocessor-controlled device with x-ray tube Mo and goniometer designed for conducting a wide variety of experiments in x-ray physics. The high-voltage system, x-ray tube and experiment chamber are all within a radiation-proof housing. German type approval as school x-ray...
Click to view
554831 Goniometer
With two independently controllable stepping motors which move the sensor and target arm. The motion is defined using the key in the control panel of the X-ray apparatus. (554 800 and 554 801) and initiated manually or automatically. Included in the scope of supply of the X-ray apparatus (554 801).
Click to view
554832 Set of Absorber Foils for X-Ray Apparatus (554832)
For X-Ray Apparatus 554 800/801. Foils mounted in frame for attaching to silt diaphram collimator or counter-tube holder.
Click to view
554834 Absorbtion Accessory X-ray (554834)
For x-ray apparatus (554801) Two absorbers for quantitative investigation of the attenuation of x-rays as a function of the thickness and the atomic number of the absorber.
Click to view
554836 Compton Accessory X-Ray (554836)
For x-ray apparatus (554 801) for investigation the Compton effect by means of wavelenth dependant transmission as a function of the placement of the Cu filter in front of or behind the aluminum scattering body; with aluminum scattering body and copper filter in frame.
Click to view
5548371 Compton Accessory X-Ray II
For investigating the Compton-effect on X-ray radiation in combination with the X-ray energy detector (559 938) and the X-ray apparatus (554 801). Consists of a circular collimator and a Plexiglas radiation body.
Technical Data
Dimensions: 25 mm x 25 mm x 6 mm
Click to view
554838 Film Holder X-Ray (554838)
For x-ray apparatus 554 800/801, with printed scale for defined positioning of films for transillumination, Laue diagrams and Debye-Scherrer photographs; includes experiment rail with millimeter scale and pinhole diaphram D=1 mm for attaching to silt-diaphragm collimator.
Suitable x-ray...
Click to view
