X-Ray Apparatus
| Klinger Educational Products. Corp. is the U. S. authorized distributor for this world renown supplier of quality science demonstration equipment. |
55477 LiF Crystal for Bragg Reflection (55477)
Designed to fit the goniometer of the x-ray apparatus(554 801). For experiments in Braggs configuration, e.g. diffraction(up to the 5th order), x-ray spectra, wavelength determination, Duane and Hunts displacement law, determining Planks constant, dependence of absorbtion on wavelength,...
Click to view
55478 NaCl Crystal for Bragg Reflection (55478)
Designed to fit the goniometer of the x-ray apparatus(554 801). For experiments in Braggs configuration, e.g. diffraction(up to the 5th order), x-ray spectra, wavelength determination, Duane and Hunts displacement law, determining Planks constant, dependence of absorbtion on wavelength,...
Click to view
554801 X-ray Apparatus Mo, Complete
Fully-featured, microprocessor-controlled device with x-ray tube Mo and goniometer designed for conducting a wide variety of experiments in x-ray physics. The high-voltage system, x-ray tube and experiment chamber are all within a radiation-proof housing. German type approval as school x-ray...
Click to view
554831 Goniometer
With two independently controllable stepping motors which move the sensor and target arm. The motion is defined using the key in the control panel of the X-ray apparatus. (554 800 and 554 801) and initiated manually or automatically. Included in the scope of supply of the X-ray apparatus (554 801).
Click to view
554832 Set of Absorber Foils for X-Ray Apparatus (554832)
For X-Ray Apparatus 554 800/801. Foils mounted in frame for attaching to silt diaphram collimator or counter-tube holder.
Click to view
554834 Absorbtion Accessory X-ray (554834)
For x-ray apparatus (554801) Two absorbers for quantitative investigation of the attenuation of x-rays as a function of the thickness and the atomic number of the absorber.
Click to view
554836 Compton Accessory X-Ray (554836)
For x-ray apparatus (554 801) for investigation the Compton effect by means of wavelenth dependant transmission as a function of the placement of the Cu filter in front of or behind the aluminum scattering body; with aluminum scattering body and copper filter in frame.
Click to view
5548371 Compton Accessory X-Ray II
For investigating the Compton-effect on X-ray radiation in combination with the X-ray energy detector (559 938) and the X-ray apparatus (554 801). Consists of a circular collimator and a Plexiglas radiation body.
Technical Data
Dimensions: 25 mm x 25 mm x 6 mm
Click to view
554838 Film Holder X-Ray (554838)
For x-ray apparatus 554 800/801, with printed scale for defined positioning of films for transillumination, Laue diagrams and Debye-Scherrer photographs; includes experiment rail with millimeter scale and pinhole diaphram D=1 mm for attaching to silt-diaphragm collimator.
Suitable x-ray...
Click to view
554840 Plate Capacitor X-Ray (554840)
For x-ray apparatus 554 800/801 for measuring ionization current and determining the ion dose rate; electrical connections via 4 mm safety sockets and BNC socket. 3 plug-inmounting pins for defined setup of plate capacitor in the experiment zone.
Click to view
554842 Set of 2 Crystal Powder Holders (554842)
For pressing a crystal powder and then measuring the X-ray diffraction spectrums with powder samples in the x-ray apparatus (554 801).
Click to view
554844 Set of Targets K-Line Fluorescence
For recording the X-ray fluorescence spectrum of different elements in the X-ray apparatus (554 801)in connection with the X-ray energy detector (559 938), Sensor-CASSY (524 010USB) and MCA box (524 058).
Technical Data
Materials: Ti, Fe, Ni, Cu, Zn, Zr, Mo, Ag Dimensions: 25...
Click to view
554846 Set of Targets L-Line Fluorescence
For recording the X-ray fluorescence spectrum of different elements in the X-ray apparatus (554 801) in connection with the X-ray energy detector (559 938), Sensor-CASSY (524 010USB) and MCA box (524 058).
Technical Data
Materials: Ag, In, Sn, W, Au, Pb Dimensions: 25 mm x 25 mm
Click to view
554848 Set of Targets Alloys
For recording the X-ray fluorescence spectrum of different alloys in the X-ray apparatus (554 801) in connection with the X-ray energy detector (559 938), Sensor-CASSY (524 010USB) and MCA box (524 058).
Technical Data
Materials: special steel (X5CrNi18-10), brass (CuZn36),...
Click to view
554861 X-ray tube Mo (554861)
Directly heated hot cathode tube with screw thread for heat sink and two-pin plug socket for cathode heating for X-ray apparatus (554 800 / 554 801).
Technical Data � Anode material: Molybdenum � characteristic radiation: K� =71.1 pm (17.4 kev), K� =63.1 pm (19.6 keV) �...
Click to view
554862 X-ray tube Cu (554862)
Directly heated hot cathode tube with screw thread for heat sink and two-pin plug socket for cathode heating for X-ray apparatus (554 800 / 554 801).
Technical Data � Anode material: Copper � characteristic radiation: K� = 154 pm (8.04 kev), K� = 139 pm (8.91 keV) � Max....
Click to view
554863 X-ray tube Fe (554863)
Directly heated hot cathode tube with screw thread for heat sink and two-pin plug socket for cathode heating for X-ray apparatus (554 800 / 554 801). Technical Data � Anode material: Iron � characteristic radiation: K� = 194 pm (6.40 kev), K� = 176 pm (7.06 keV) � Max. emission...
Click to view
554864 X-ray tube Ag (554864)
Directly heated hot cathode tube with screw thread for heat sink and two-pin plug socket for cathode heating for X-ray apparatus (554 800 / 554 801).
Technical Data
Anode material: Tungsten characteristic radiation: La = 148 pm (8.39 kev), L� = 128 pm (9.67 keV) Max. emission...
Click to view
554865 X-ray tube W(554865)
Directly heated hot cathode tube with screw thread for heat sink and two-pin plug socket for cathode heating for X-ray apparatus (554 800 / 554 801).
Technical Data � Anode material: Tungsten � characteristic radiation: La = 148 pm (8.39 kev), L� = 128 pm (9.67 keV) � Max....
Click to view
559938 X-Ray Energy Detector (559938)
The energy detector is designed for use with the x-ray apparatus 554 801, recording energy separated measurements within the x-ray spectrum. The detector expands the range of experiments possible in quantum and atomic physics, and will also perform non-destructive material analysis.
Click to view
