524 010 Sensor-CASSY�
Overview
Cascadable interface for measured-value recording.
for connection to the RS-232 serial interface of a computer, another CASSY module or the CASSY display
Sensor-CASSY and Sensor-CASSY USB can be used mixed
fourfold electrically isolated (inputs A and B, relay R, voltage source S).
cascading of up to 8 CASSY modules possible (to multiply the inputs and outputs)
up to 8 analog inputs per Sensor-CASSY retrofittable using sensor boxes
automatic sensor box detection by CASSY Lab (524 200) - plug and play -
microprocessor-controlled via the CASSY operating system (complete with software update functionality for fast, easy performance enhancements)
can be set up as a benchtop, console or demonstration unit (also suitable for CPS/TPS panel frames)
voltage supply 12 V AC/DC via cannon plug or an adjacent CASSY module
Note: also available with USB port (524 010USB)
Technical Data
5 analog inputs (any two inputs A and B usable simultaneously)
2 analog voltage inputs A and B on 4-mm safety sockets
Resolution: 12 bits
Measuring ranges: � 0,3/1/3/10/30/100 V
Measurement error: � 1 % plus 0.5 % of range end value
Input resistance: 1 MΩ
Scanning rate: max. 200,000 values/s (= 100,000 values/s per input)
Number of measured values: nearly unlimited (depends on PC) up to 100 values/s, at higher measuring rate max. 32,000 values (= 16,000 values per input)
1 analog current input A on 4-mm safety sockets
Measuring ranges: � 0.1/0.3/1/3 A
Measurement error: voltage error plus 1 %
Input resistance: < 0.5 Ω (except under overload)
See voltage inputs for further data
2 analog inputs at sensor box connector sites A and B
(All CASSY sensor boxes and sensors can be connected)
Measuring ranges: � 0.003/0.01/0.03/0.1/0.3/1 V
Input resistance: 10 kΩ
See voltage inputs for further data
The technical data will change according to a connected sensor box. In this case, the CASSY Lab automatically detects the possible measurement quantities and ranges when a sensor box is attached.
4 timer inputs with 32-bit counters at sensor box site (e.g. for BMW box, GM box or timer box)
Counting frequency: max. 100 kHz; time resolution: 0.25 �s
Measuring time between two events at same input: min. 100 �s
Measuring time between two events at different inputs: min. 0.25 �s
Memory: max. 10,000 time points (= 2,500 values per input)
1 changeover relay (with LED to indicate switching state)
Range: max. 100 V / 2 A
1 analog output (PWM-output) (pulse-width modulated, switchable voltage source, LED switching state indicator, e.g. for holding magnet or supplying the experiment)
Variable voltage range: max. 16 V / 200 mA (load ≥ 80 Ω)
PWM range: 0% (off), 5-95% (1% resolution), 100% (on)
PWM frequency: 100 Hz
12 digital inputs (TTL) on sensor box sites A and B (at present only used for automatic sensor box detection)
6 digital outputs (TTL) on sensor box sites A and B (at present only used for automatic switching of the measuring range of a sensor box)
1 serial interface RS232 (subD-9) for connection to a computer
1 CASSY bus for connecting additional CASSY modules
Dimensions: 115 mm x 295 mm x 45 mm
Weight: 1 kg
Scope of delivery
1 Sensor-CASSY
1 CASSY Lab software, without activation code, with comprehensive help function (20 sessions free, then usable as demo version)
1 Installation manual
1 Serial cable (subD-9)
1 Plug-in supply unit 12 V/ 1.6 A
for connection to the RS-232 serial interface of a computer, another CASSY module or the CASSY display
Sensor-CASSY and Sensor-CASSY USB can be used mixed
fourfold electrically isolated (inputs A and B, relay R, voltage source S).
cascading of up to 8 CASSY modules possible (to multiply the inputs and outputs)
up to 8 analog inputs per Sensor-CASSY retrofittable using sensor boxes
automatic sensor box detection by CASSY Lab (524 200) - plug and play -
microprocessor-controlled via the CASSY operating system (complete with software update functionality for fast, easy performance enhancements)
can be set up as a benchtop, console or demonstration unit (also suitable for CPS/TPS panel frames)
voltage supply 12 V AC/DC via cannon plug or an adjacent CASSY module
Note: also available with USB port (524 010USB)
Technical Data
5 analog inputs (any two inputs A and B usable simultaneously)
2 analog voltage inputs A and B on 4-mm safety sockets
Resolution: 12 bits
Measuring ranges: � 0,3/1/3/10/30/100 V
Measurement error: � 1 % plus 0.5 % of range end value
Input resistance: 1 MΩ
Scanning rate: max. 200,000 values/s (= 100,000 values/s per input)
Number of measured values: nearly unlimited (depends on PC) up to 100 values/s, at higher measuring rate max. 32,000 values (= 16,000 values per input)
1 analog current input A on 4-mm safety sockets
Measuring ranges: � 0.1/0.3/1/3 A
Measurement error: voltage error plus 1 %
Input resistance: < 0.5 Ω (except under overload)
See voltage inputs for further data
2 analog inputs at sensor box connector sites A and B
(All CASSY sensor boxes and sensors can be connected)
Measuring ranges: � 0.003/0.01/0.03/0.1/0.3/1 V
Input resistance: 10 kΩ
See voltage inputs for further data
The technical data will change according to a connected sensor box. In this case, the CASSY Lab automatically detects the possible measurement quantities and ranges when a sensor box is attached.
4 timer inputs with 32-bit counters at sensor box site (e.g. for BMW box, GM box or timer box)
Counting frequency: max. 100 kHz; time resolution: 0.25 �s
Measuring time between two events at same input: min. 100 �s
Measuring time between two events at different inputs: min. 0.25 �s
Memory: max. 10,000 time points (= 2,500 values per input)
1 changeover relay (with LED to indicate switching state)
Range: max. 100 V / 2 A
1 analog output (PWM-output) (pulse-width modulated, switchable voltage source, LED switching state indicator, e.g. for holding magnet or supplying the experiment)
Variable voltage range: max. 16 V / 200 mA (load ≥ 80 Ω)
PWM range: 0% (off), 5-95% (1% resolution), 100% (on)
PWM frequency: 100 Hz
12 digital inputs (TTL) on sensor box sites A and B (at present only used for automatic sensor box detection)
6 digital outputs (TTL) on sensor box sites A and B (at present only used for automatic switching of the measuring range of a sensor box)
1 serial interface RS232 (subD-9) for connection to a computer
1 CASSY bus for connecting additional CASSY modules
Dimensions: 115 mm x 295 mm x 45 mm
Weight: 1 kg
Scope of delivery
1 Sensor-CASSY
1 CASSY Lab software, without activation code, with comprehensive help function (20 sessions free, then usable as demo version)
1 Installation manual
1 Serial cable (subD-9)
1 Plug-in supply unit 12 V/ 1.6 A